Common troubleshooting and daily maintenance guide for spiral duct machine

Products

Common troubleshooting and daily maintenance guide for spiral duct machine

——BYFO equipment maintenance manual

Spiral duct machine is the core equipment of air duct processing enterprises, and its operating status directly affects production efficiency and product quality. However, even the most sophisticated equipment, without proper maintenance and use, will gradually experience various malfunctions, affecting production progress and increasing maintenance costs. Instead of waiting for the equipment to strike before repairing, it is better to maintain it carefully on a daily basis to prevent problems before they arise.

Based on years of experience in duct equipment manufacturing and after-sales service, BYFO has compiled this guide for troubleshooting and maintenance of spiral duct machines to help your equipment maintain optimal condition in the long term.

Ⅰ. Common troubleshooting and solutions

Fault 1: The shape of the air duct is not round

Phenomenon description:

The cross-section of the formed air duct is elliptical or irregular, and the roundness exceeds the standard, which affects the subsequent connection and installation.

Possible reasons:

1. Improper adjustment of the gap between the forming rollers

2. The thickness of the sheet does not match the equipment settings

3. The forming roller is severely worn

4. Improper feeding and deviation of the sheet material

Troubleshooting steps:

1. Check if the thickness of the sheet is within the processing range of the equipment

2. Measure the gap between the forming rollers to confirm whether it meets the thickness requirements of the sheet metal

3. Observe whether there are obvious wear marks on the surface of the forming roller

4. Check if the feed guide device is aligned to the center

Solution:

-Adjust the gap between the forming rollers again, usually the gap should be 0.8-0.9 times the thickness of the sheet

-Replace severely worn forming rollers

-Adjust the feeding guide wheel to ensure that the sheet is fed in the center

Preventive measures:

-Regularly check the wear of the forming rollers

-When switching between sheets of different thicknesses, it is necessary to readjust the roller gap

Fault 2: The bite is loosed or detached

Phenomenon description:

The bite of the air duct is not fully compressed, and there is obvious looseness when pressed by hand, and it can even be separated with slight force.

Possible reasons:

1. Insufficient pressure of bite device

2. Wear and tear of bite mold

3. High rebound rate of sheet metal (such as stainless steel material)

4. Insufficient bite depth

Troubleshooting steps:

1. Check if the pressure of the bite device is normal

2. Observe whether the edge of the bite mold is worn

3. Use a caliper to measure whether the bite depth meets the standard

Solution:

-Adjust the pressure of the bite device and increase the clamping force

-Replace worn bite molds

-For high rebound materials, the bite depth can be appropriately increased or pre pressing technology can be used

Preventive measures:

-Check the bite quality every shift and adjust it promptly if any looseness is found

-Reduce production speed appropriately before processing hard materials such as stainless steel

Fault 3: Cutting burrs are severe

Phenomenon description:

The edge of the cut spiral duct has a large number of burrs, which require secondary polishing and affect installation efficiency and safety.

Possible reasons:

1. Cutting blade wear

2. Improper setting of cutting gap

3. Cutting speed too fast

4. Abnormal hardness of the sheet

Troubleshooting steps:

1. Observe whether the cutting blade becomes dull or has a notch

2. Check the gap between the cutting blades

3. Check the running speed during cutting

Solution:

-Replace the cutting blade with a new one

-Adjust the blade clearance, usually 10% -15% of the sheet thickness

-Reduce cutting speed appropriately, especially for thick sheets or hard materials

Preventive measures:

-Establish blade replacement records and regularly replace them

-Keep the blade clean and avoid sticking metal shavings

Fault 4: Abnormal noise or vibration during operation

Phenomenon description:

The equipment makes abnormal noise during operation, or there is obvious vibration on the body.

Possible reasons:

1. Bearing damage or poor lubrication

2. Loose transmission chain/belt

3. The forming roller gets stuck with foreign objects

4. Loose foundation bolts of the equipment

Troubleshooting steps:

1. Turn off the equipment and manually turn the wheel to feel the resistance

2. Check whether there is any abnormal noise or heating in each bearing part

3. Observe whether the transmission components are loose

4. Check the tightening condition of the foundation bolts

Solution:

-Add lubricating oil or replace damaged bearings

-Adjust the tension of the chain/belt

-Clean up foreign objects between the forming rollers

-Re tighten the foundation bolts

Preventive measures:

-Check the transmission components before starting up daily

-Keep the equipment clean and prevent debris from entering

Fault 5: Poor feeding or stuck material

Phenomenon description:

The sheet gets stuck, slips or deviates during the feeding process.

Possible reasons:

1. Insufficient pressure on the feeding roller

2. Oil stains or debris on the surface of the sheet

3. Wear of feeding roller

4. Excessive curling of the sheet

Troubleshooting steps:

1. Check if the pressure of the feeding roller is sufficient

2. Observe whether the surface of the sheet is clean

3. Check if the surface pattern of the feeding roller is worn

Solution:

-Increase the pressure of the feeding roller

-Clean the oil stains on the surface of the sheet

-Replace worn feeding rollers

-For severely curled sheets, perform pre leveling first

Preventive measures:

-Pay attention to moisture and dirt prevention when storing sheets

-Regularly clean the feeding roller

Fault 6: Control system alarm

Phenomenon description:

The touch screen displays a fault code, and the equipment cannot start normally or run.

Possible reasons:

1. Abnormal sensor signal

2. Motor overload

3. Encoder malfunction

4. Program parameter error

Troubleshooting steps:

1. Record the alarm code and refer to the instruction manual

2. Check if all sensors are sensing properly

3. Check if the motor current exceeds the limit

4. Confirm whether the parameter settings are correct

Solution:

Handle according to the alarm code guidance

Clean the dirt on the surface of the sensor

Reset the overload protector

Re calibrate or restore factory parameters

Preventive measures:

Regularly check the cleanliness of sensors

Operators should be familiar with the meaning of basic alarm codes

Ⅱ. Daily maintenance plan

2.1 Daily maintenance (per shift)

Maintenance itemsOperation contentPoints for attention
Equipment cleaningRemove metal shavings and dust from the fuselage, forming rollers, and cutting areasTake precautions to protect electrical components when using air gun purging
Lubrication inspectionCheck the oil level at all lubrication points and add lubricating oil as neededUse the specified grade of lubricating oil
Bite inspectionInspect the quality of the finished air duct bite and confirm there is no loosenessStop the system immediately to adjust when issues are detected
Abnormal sound monitoringPerform idle rotation upon startup and listen for any abnormal noisesShut down for inspection during abnormal conditions
Safety deviceCheck whether the emergency stop button and protective cover are functioning properlyEnsure the safety device is sensitive and reliable

2.2 Weekly maintenance

Maintenance itemsOperation contentPoints for attention
Transmission componentsCheck the chain tension and adjust or add lubricating grease if necessary.Excessive chain slack can cause tooth skipping.
Tightening inspectionCheck whether the anchor bolts and all connecting bolts are looseThe inspection frequency for vibration environments should be increased.
Electrical inspectionCheck for looseness or heating at wire jointsPower-off procedure, safety precautions
Forming roller cleaningRemove adhesive residues from the roller surface and inspect for wear conditionsSevere wear requires prompt replacement
Feeding roller cleaningClean the surface of the feeding roller and inspect for pattern wear.Wear of patterns may lead to slippage

2.3 Monthly maintenance

Maintenance itemsOperation contentPoints for attention
Gearbox oil changeInspect the gearbox oil quality and replace it when necessary.Oil change is required after 500 hours of first use
Bearing lubricationAdd grease to all bearing housingsAvoid overfilling
Cutting bladeCheck the blade sharpness and grind or replace it when necessary.Blade passivation affects incision quality
Belt inspectionInspect belt wear and tensionReplace worn belts promptly
Pneumatic systemInspect the air source triple assembly, clean the filter, and check the oil mister.Unstable atmospheric pressure affects the operation of actuating elements

2.4 Quarterly maintenance

Maintenance itemsOperation contentPoints for attention
Accuracy calibrationCheck the precision of fixed-length cutting and calibrate the encoder if necessary.Precision deviation may affect product dimensions
Forming roller inspectionComprehensive inspection of forming roller wear conditionWear exceeding limits affects roundness
Electrical cabinet cleaningClean the dust inside the electrical cabinet and inspect the cooling fanDust accumulation may lead to poor heat dissipation
Mold inspectionInspect the bite mold for wearMold wear affects bite quality
Complete machine inspectionConduct a comprehensive inspection of all equipment components to identify potential hazardsRecommended for professional execution

Ⅲ. List of vulnerable parts and replacement cycle

Vulnerable parts nameNormal service lifeReplacement criteriaRemarks
Cutting blade200,000 to 500,000 metersSignificant increase in surgical incision burrsReplace after 2-3 cycles of grinding
Forming roller1 to 2 million metersSurface wear and reduced roundnessDependent on sheet thickness and material
Bite mold500,000 to 1,000,000 metersBite loss and dimensional deviationStainless steel processing reduces service life by half
Feeding roller500,000 to 800,000 metersSurface pattern is smoothed and slipperyRemovable for refurbishment
Bearing1 to 2 yearsAbnormal noise, heat generation, large clearanceRegular lubricant replenishment prolongs service life
Transmission chain1 to 2 yearsElongation exceeding 5%, tooth skippingMaintain appropriate tension
BeltOne yearCracks, aging, slippingReplace in pairs
Seal ringOne yearLeaky hardeningKey components of pneumatic systems

Ⅳ. BYFO’s after-sales service guarantee

To ensure that your equipment is always in the best condition, BYFO provides comprehensive after-sales support:

4.1 Remote technical support

-7 x 24-hour phone response

-Remote video guidance for troubleshooting

-Direct delivery of accessories by express

4.2 On site service

-Engineer on-site installation and debugging

-Engineer on-site maintenance

4.3 Regular inspection

-Optional annual inspection service

-Early detection of potential faults

-On site operation training

4.4 Accessory Supply

-Adequate inventory of original factory accessories

-Recommended inventory list of vulnerable parts

-Emergency parts shipped 24 hours a day

Ⅴ. Conclusion

Spiral duct machine is the core productivity of air duct processing enterprises, and its operating status directly affects production efficiency and product quality. Through regular maintenance and timely troubleshooting, not only can the service life of the equipment be extended, but the losses caused by unexpected shutdowns can also be reduced.

Remember: the best maintenance is preventive maintenance.

BYFO company has always been committed to providing customers with high-quality air duct equipment and professional technical support. If you encounter any problems during the use of the equipment or need more detailed operation guidance, please feel free to contact us at any time.

Does the equipment need maintenance? Or do you encounter a malfunction?

Welcome to contact BYFO after-sales service center, we will provide you with the most professional support and solutions.

Related Products

Customer message

Scroll to Top

Customer message